InputOM ii+ [D>=13]

NOTICE: We are updating our website. For product enquiries and orders please contact us directly.
NOTICE: SPLat Controls has moved. We are now at 1/85 Brunel Rd, Seaford, 3198. map

InputOM ii+ [D>=13]

Pushes the on/off state of 8 output points ii through ii+7 to X in individual bits of X. An On output gives a '1', an Off output gives a '0'.

The operand ii may be any number that exists as an input. Input points that don't exist return 0's in the corresponding bit positions in X.

+ From dialect 16 the address argument will be jndexed when executed inside a MultiTrack task and will be indexed if the instruction is preceded by the IasJ: precode.

This instruction will not readback an output ON condition resulting from an fPulse0 instruction.

Dialect restriction. InputOM is implemented only in dialects 13 or later.

See also OutputM, InputO